Wood Column Design Step by Step — Worked Example, Column Stability Factor CP (NDS 2024)

2:01Published July 8, 2026Narrated, with captions and a full transcriptAlso on YouTube

Design a wood column in StructSuite per NDS 2024, start to finish: unbraced length and end conditions, species and grade read straight off the NDS Supplement tables, the adjustment factors, and the column stability factor CP that actually decides the answer. The first section is overstressed and fails, and the fix happens on screen.

Transcript and details

About this video

What you will see

  • Starting from an empty module, every input entered on camera
  • Step 1: the column's unbraced length, 8 ft
  • The end-condition buckling mode picked from NDS Table G1 (Appendix G), with a diagram of how the column buckles in each mode. Fixed at both ends but free to sway gives Ke = 1.2
  • Each finished step collapsing to a blue summary line
  • Step 2: dead and live axial loads entered separately by ASCE 7-22 load type, with member self-weight added into D automatically, and CD taken from the governing ASD combination (NDS Table 2.3.2)
  • Step 3: Douglas Fir-Larch No. 2 selected from the real NDS Supplement Table 4A rows, Fb = 900 and Ft = 575 psi on the row as it is clicked
  • The section chosen from NDS Supplement Table 1B, so a 4x6 is the dressed 3.5 in x 5.5 in it really is
  • Step 4: the NDS adjustment factors, wet or dry service (CM), temperature (Ct) and incising (Ci)
  • Step 5: the 4x6 comes back overstressed and fails, because weak-axis slenderness, not axial stress, limits the capacity
  • Going back for a deeper section and re-running until every demand-capacity ratio is under 1.0
  • A load-combination row opened to show fc = P/A, Fc* = Fc x CM x Ct x CF x Ci x CD, CP per NDS 3.7.1.5 Eq. 3.7-1, F'c = Fc* x CP, and the ratio

The column in this example

8 ft unbraced height, fixed-fixed with sway, Ke = 1.2 from NDS Table G1, so Le = 1.2 x 96 in = 115.2 in. Axial dead load 4000 lb and live load 5000 lb, plus the member's own self-weight. Douglas Fir-Larch No. 2 from NDS Supplement Table 4A: Fc = 1350 psi, Fb = 900 psi, Ft = 575 psi, E = 1,600,000 psi, Emin = 580,000 psi. The first trial, a 4x6 (dressed 3.5 in x 5.5 in, A = 19.25 sq in), fails. Both trial sections are only 3.5 in wide, so buckling is governed by the weak axis at Le/d = 115.2/3.5, about 32.9, unchanged by going deeper. The fix is a 4x8 (dressed 3.5 in x 7.25 in, A = 25.38 sq in), which wins on area, and it passes. Behind CP: NDS 3.7.1.5 Eq. 3.7-1 with FcE = 0.822 Emin' / (Le/d) squared and c = 0.8 for sawn lumber, holding Le/d to the 50 limit of NDS 3.7.1.4.

Codes referenced: NDS 2024 Section 3.7, 3.7.1.4, 3.7.1.5 Eq. 3.7-1, Table 2.3.2, Table 2.3.3, Appendix G Table G1; NDS Supplement Tables 1B and 4A; ASCE 7-22 Chapter 2.

Transcript

The narration word for word, 231 words, from the video's own captions. Select a time to play from there.

Wood Column — design per 2024 NDS

0:06In this tutorial we'll design a wood column per the 2024 NDS — its axial capacity with the column-stability factor CP.

Add the Wood Column module

0:15From the dashboard, add the Wood Column module. It opens empty. Step one, geometry. Enter the column's unbraced length — eight feet. Then pick the end-condition buckling mode from NDS Table G-1 — each diagram shows how the column buckles. Here we choose fixed at both ends but free to sway, giving a Ke of one-point-two.

Step complete — blue summary

0:35The step collapses to a blue summary. Step two, the axial loads. Enter the dead and live loads the column carries — four thousand and five thousand pounds. Self-weight is added automatically.

Loads summarized

0:48Collapse it, and the loads are summarized. Step three, material and section. Select Douglas Fir-Larch, Number 2, straight from the NDS Supplement tables.

First try a 4x6

0:59For the section, first try a four-by-six. Collapse the section. Step four sets the NDS adjustment factors — wet or dry service, temperature, and incising. The defaults suit a typical dry, interior column.

Step 5 — the 4x6 fails

1:29Step five checks it. The four-by-six is overstressed and fails — the weak-axis slenderness limits its capacity. So go back to step three and choose a deeper section.

Choose a 4x8

1:39A four-by-eight. Back to verification — now every demand-capacity ratio is under one. The column passes. Open any load combination to see the full column-stability and capacity calculation.

Done — a passing wood column

1:55And that's a complete wood-column design, ready for your report.