Add a module from the list on the leftabove, or reopen one of your projects.
See every module at work
1 of 12 · A new wood beam, from an empty module · Click the module to scroll and edit it
Create plan-check-ready structural calculations
StructSuite is a free, browser-based structural design and load calculation app for residential and light-frame buildings. It designs wood and steel beams and columns, floor and ceiling joists, rafters and headers, wood-frame shear walls with their hold-downs, isolated and strip footings and concrete or masonry cantilever retaining walls, calculates dead, live, seismic and wind loads, and assembles the checks into a plan-check-ready calculation report to NDS 2024, SDPWS 2021, AISC 360-22, ACI 318-25, TMS 402-22, ASCE 7-22 and the 2024 IBC.
Free to use, in full, with no account.
Design modules
What each module designs
Three lines on each module, written from the module itself. Open the details for what it takes in, how it designs it and what it draws, or start it here with no account.
Cover Sheet
Page one of the printed report
- Three layouts: Standard title block, Showcase on a photo background, or a Blank canvas.
- Fourteen switchable blocks: title, address, owner, engineer of record, stamp, signature, notes.
- Prints as page one on US Letter, ahead of the table of contents and the verification page.
Dead and Live Loads
ASCE 7-22 Tables C3.1-1a and 4.3-1
- Dead loads built assembly by assembly from ASCE 7-22 Table C3.1-1a.
- Light, Typical and Heavy presets, plus your own lines such as rooftop PV.
- Live loads by occupancy from Table 4.3-1, with the roof live load and handrail loads.
What it takes in, designs and draws
Dead loads built up from the table, live loads by occupancy, per ASCE 7-22.
Dead loads
ASCE 7-22 Table C3.1-1a
- The whole table to pick from, in its own order and categories, thickness-priced items scaled by the thickness entered
- A roof, a ceiling, any number of floors, interior and exterior walls
- Light, Typical and Heavy presets for every assembly; a duct allowance; your own lines, such as rooftop PV
- Wood framing as its own computed line; a roof slope entry that also prints D on the horizontal projection
- A live section of each assembly — finish, sheathing, joists at their spacing, ceiling — labelled line by line
Live loads
ASCE 7-22 Table 4.3-1
- Shown in full in the book's order and columns; picked rows print under the table's own headings
- The roof live load Lr, the handrail loads of §4.5.1 and the partition live load of §4.3.2
- A Residential preset of eight rows
- No live-load reduction applied — a reduced L is entered if one is taken
- A Visualization step: each assembly drawn in section, and a building section with D and L on every plane, shown for all, dead or live loads
In the report
One section, first by default
- Each assembly's total dead load D in psf
- The summary becomes a calculation section and reorders with the dashboard
Seismic Loads
ASCE 7-22 Chapter 12, Equivalent Lateral Force
- Site class, SDC and the full Table 12.2-1 picked from the code's own tables.
- Period by Table 12.8-2, by 0.1N, by the Cw method, or typed and capped at Cu·Ta.
- Base shear, story forces, overturning and diaphragm forces, with four diagrams.
What it takes in, designs and draws
Equivalent Lateral Force per ASCE 7-22 Chapter 12, every table in the code's own layout.
Code tables, picked on a click
Shown as the book prints them
- Site Class (Table 20.2-1), Risk Category and Ie (Tables 1.5-1, 1.5-2)
- SDC from Tables 11.6-1 and 11.6-2, with the §11.6 exception
- Full Table 12.2-1 in lettered groups, the project's SDC column highlighted
- R, Ω0 and Cd set on a click; Not Permitted and height limits flagged
- Footnote b reduction of Ω0 for flexible diaphragms; footnotes a to q in full
Period and C_s
§12.8 with every limit named
- T by Ct·hnx (Table 12.8-2), by 0.1N with eligibility checked, by the Cw method, or typed and capped at Cu·Ta
- Cs from Eq. 12.8-3 with the 12.8-4 to 12.8-7 limits and the governing one named
- The §12.8.1.3 cap as a seven-criteria checklist, five checked automatically
- A design-spectrum chart with the project's T marked
Forces and diagrams
Strength E and allowable 0.7E
- Base shear V, story forces Fx with Cvx and k, story shears Vx, overturning Mx
- Diaphragm forces Fpx per §12.10.1.1 with the 0.2 and 0.4·SDS·Ie·wpx bounds
- Four force diagrams — story forces, story shear, overturning, diaphragm — with values labelled
- Every row opens to its substitutions
Wind Loads
ASCE 7-22 Chapters 27, 28 and 30
- Directional (Chapter 27) and envelope (Chapter 28) procedures, every line substituted.
- The four Figure 27.3-8 load cases with torsion, roof uplift and the minimum loads.
- Story forces by level for a multi-story building; components and cladding (Chapter 30).
What it takes in, designs and draws
MWFRS by the directional (Chapter 27) and envelope (Chapter 28) procedures of ASCE 7-22, and components and cladding by Chapter 30 Part 1.
Three chapters
Chapters 27, 28 and 30
- Directional: pressures on every surface, wind perpendicular and parallel to the ridge, both internal-pressure signs
- Both Figure 27.3-1 windward-roof Cp values run (Note 3), the windward wall stepped with height
- Envelope: Load Cases 1 to 4, zones of Figures 28.3-1 and 28.3-2 interpolated by roof angle, edge-zone width a
- The §28.3.2 torsional exception, the §28.3.2.1 distance rule, the §28.3.3 walls-only floor
- Components and cladding (optional step): walls, gable, hip and monoslope roofs (Figures 30.3-1, 30.3-2A–2G, 30.3-5A/5B), overhangs and parapets
Tables in the code's layout
Nothing assumed
- Kd (Table 26.6-1), Ke (26.9-1), Kz and Kh (26.10-1), enclosure (26.13-1)
- Exposure per §26.7 and Kzt from Figure 26.8-1, with the clause beside them
- qz at every height from grade to the ridge; leeward Cp interpolated on L/B with the trace shown
- Roof Cp grid by h/L and θ with the footnote b area reduction; enclosure computed from opening areas
Load cases and diagrams
Drawn with the values on them
- The four Figure 27.3-8 cases (1, 0.75, 0.75, 0.563), eccentricity and torsional moment Mz
- Base shear in both directions with the gable-end triangle counted; roof uplift; the Appendix D exemption
- Roof overhang (§27.3.3 / §28.3.5) and parapet (§27.3.4 / §28.3.4, at qp): the net on each drawn in section, the parapet force per direction
- Elevation, plan and sidewall views, one resultant per surface; the §27.1.5 and §28.3.6 minimum loads drawn; W and 0.6W, governing case flagged
- Story forces by level for a multi-story building: story shear, overturning and torsion, with story force diagrams
Wood & Steel Beam
NDS 2024 · AISC 360-22
- Multi-span beams, cantilevers and sloped members; uniform, partial, trapezoidal and point loads.
- Sawn lumber, glulam, I-joists, LVL, LSL and PSL, or AISC W-shapes, HSS and pipe.
- Shear, moment and deflection diagrams for every load combination; Simpson hanger selection.
What it takes in, designs and draws
Wood per NDS 2024 and steel per AISC 360-22, on the same solver and the same report.
Spans and loads
Any beam a house has
- Single-span or continuous multi-span; pinned, roller, fixed or free supports — cantilevers and overhangs
- Sloped members entered as a pitch or an angle
- Uniform, partial, triangular, trapezoidal, point and applied-moment loads, upward loads included
- Pattern live loading per §4.3.3; an in-browser solver pinned to all 32 AWC Design Aid No. 6 cases
Wood and steel sections
From the source, with its number
- Sawn lumber from Supplement Tables 4A, 4B and 4D; glulam from 5A and 5B, in the code's layout
- I-joists (TJI, BCI, LPI), LVL, LSL and PSL from the manufacturer's ICC-ES report, linked
- Steel W-shapes, rectangular, square and round HSS and pipe from the AISC Shapes Database
- Compactness and lateral-torsional buckling per Chapter F; bearing per §J10
Checks and diagrams
Every case, every combination
- Flexure, shear, live and total deflection against IBC Table 1604.3 presets with creep; bearing with Cb
- Glulam sagging and hogging against Fbx+ and Fbx−; I-joists against MR and VR
- Every ASD combination at its own CD; §12.4.4 cantilever uplift and overstrength when called for
- Loading, shear, moment and deflection diagrams with a cursor readout; optional Simpson hanger selection
Floor/Ceiling Joist & Rafter
2024 IBC Chapter 23 · Trus Joist TJI · TJ-9000
- 2024 IBC span tables, headers included, digitized cell by cell and shown as printed with the cell read.
- Floor joists, ceiling joists, rafters and headers: pass or fail per table, the smallest adequate size named.
- TJI spans and TJ-9000 headers, plus an allowable-span ladder and the member sketched under its loads.
What it takes in, designs and draws
The 2024 IBC prescriptive span tables and the Trus Joist tables, read cell by cell and shown as printed.
2024 IBC span tables
Digitized, never interpolated
- Tables 2308.8.2.1(1) and (2), 2308.11.1(1) and (2), 2308.11.2(1) to (6), and the header tables 2308.8.1.1(1) and (2)
- Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Fir in four grades at 12, 16, 19.2 and 24 in
- The table's own load cases: 30 or 40 psf floor live at 10 or 20 psf dead, attic with or without storage
- 20 psf roof live or 30 and 50 psf ground snow, ceiling attached or not, the rafter-tie question with Table 2308.11.2(7)
- Headers over openings in exterior and interior bearing walls: supporting, ground snow load, building width, jack studs, the unbraced-top footnote
Trus Joist
TJ-4000, TB-805, TB-824 and TJ-9000
- TJI floor, roof and ceiling joists by depth and series
- L/480 or L/360; snow and non-snow roof load columns; slope ranges
- Web-stiffener and creep notes; bearing lengths
- TJ-9000 headers: TimberStrand LSL, Microllam LVL and Parallam PSL load tables for floor, snow roof and non-snow roof
- Depths 9-1/2 to 24 in, TJI 110 to 560D by depth; floor 40 psf at L/480 or L/360; ceiling 20 or 40 psf; no hanger lookup for TJI
Result, tables and figures
A pass or fail per table, shown as printed
- The table reproduced as printed, with the row, the column and the cell the check read shaded
- A reading sheet: table, column, row, cell, footnotes applied, the span check as a D/C, every tabulated size of the row
- An allowable-span ladder and one sketch per member: a simple span on pinned supports under the table's loads in plf, named as the trade names it
- Footnotes applied: 2 in end bearing, spans over 26 ft, lumber availability over 20 ft, the header footnotes
- Optional Simpson hanger selection on the sawn-lumber joist and rafter paths, from the table load and spacing
Wood & Steel Column
NDS 2024 · AISC 360-22
- Effective length picked from the NDS Table G1 picture table, unbraced lengths per axis.
- Axial load plus a lateral wall load, combined bending and compression per NDS §3.9.2.
- Steel columns per AISC 360-22 Chapters E and H, slender elements included.
What it takes in, designs and draws
Wood columns per NDS 2024 with CP, steel columns per AISC 360-22 Chapter E.
Geometry and loads
Per axis, checked as you type
- Ke from an NDS Table G1 picture table of the six buckling modes
- Separate end conditions and unbraced lengths per axis (0 = braced continuously); a live ℓe/d ≤ 50 check
- Axial loads by ASCE 7-22 type, plus an optional lateral wall load — uniform, or a point at a height
- The moment follows the end condition: wh²/8 pinned, wh²/12 fixed, wh²/2 cantilever
Wood design, NDS 2024
Every factor walked through
- Species and grade off Supplement Tables 4A, 4B, 4D and 5B, footnotes applied and quoted
- CP recomputed for every combination at its own CD: Le, ℓe/d, Emin′, Fc*, FcE, Eq. 3.7-1
- Combined bending and compression per §3.9.2 (Eq. 3.9-3) with the P-δ amplifier; CL or Cfu
- Bearing on the plate or sill per §3.10.2 with Cb; a warning when §3.10.1.3 requires a metal plate
- Optional Simpson Strong-Tie post cap from the Post-to-Beam Selector, checked for download, uplift and lateral
Steel design and diagrams
AISC 360-22
- Chapter E from the AISC Shapes Database, slender-element sections per E7
- Combined axial plus bending per H1 with the Appendix 8 B1 amplifier; a live Lc/r ≤ 200 advisory
- Axial, shear, moment and deflection diagrams along the column for every case and combination
Wood-Frame Shear Wall
SDPWS 2021 · NDS 2024
- Draw the walls on the building plan, including L-, T- and U-shaped footprints.
- Story shear distributed to each wall line automatically, seismic by area and wind by length.
- Simpson hold-downs and SABR anchors from the catalog; end posts and collectors designed.
What it takes in, designs and draws
The building drawn on a plan; forces distributed and every wall designed per SDPWS 2021 and NDS 2024.
The building on a plan
Not a single wall line
- Letter and number grids; bays ticked to trace an L-, T- or U-shaped footprint
- Walls picked as grid segments and auto-tagged, several per line; the plan and every elevation drawn live to scale
- Story force distributed by the flexible-diaphragm tributary method — seismic by area, wind by length — with a color overlay
- An open front transfers its moment to the edge line within SDPWS §4.2.6.1
- Open-front edges checked per §4.2.6.1; notched legs, stranded lines and overlapping walls refused with the reason
Wall design, SDPWS 2021
Table 4.3A in the book's layout
- Shear shared within a line by capacity; the Table 4.3.3 aspect-ratio screen runs live
- Structural I, wood structural panel, plywood siding, particleboard and fiberboard rows; edge nailing at 6, 4, 3 and 2 in
- Footnotes 2, 3 and 10 applied; two-sided sheathing per §4.3.5.4.1; the 3x framing note per §4.3.7.1
- Gravity loads per line resist overturning at their combination factor, with Ev
- Step 8 free-body per combination, or under W or Eh alone, unfactored; Step 7 opens with the design-scope table
Hold-downs, posts and collectors
Simpson Strong-Tie from the catalog
- DTT and HDUE hold-downs, the hold-down's own CL setting the moment arm, minimum post size enforced
- SABR anchor bolts for stem walls, slab edges and garage curbs, by wind or by Seismic Design Category
- End posts per NDS 2024: compression with CP, plate bearing, net-section tension at the bolts
- Base shear transfer: sill anchor bolts (NDS Table 12E) or Simpson framing clips, every spacing a capacity cell; washer and toe-nail rules checked
- Collectors: §12.10.2.1 exception or Ω0, Fpx bounds, the §12.3.3.5 increase, F(x) drawn along the line
Isolated & Strip Footing
ACI 318-19 / 318-25 · ASCE 7-22
- Isolated and strip footings to ACI 318-19 or ACI 318-25, on concrete, masonry, steel or wood supports.
- Bearing per combination, kern-aware or biaxial with partial contact; overturning and sliding.
- One-way and punching shear, flexure, dowels and development length, with plan and section views.
What it takes in, designs and draws
Spread and strip footings per ACI 318-19 or 318-25 with the ASCE 7-22 combinations.
Footings and loads
On anything that stands on them
- Isolated (column) and strip (wall) footings; concrete, steel or wood columns; concrete, masonry, steel or wood walls
- An optional pedestal; soil and slab over the footing counted as dead load
- Load cases D, L, Lr, S, R, W and E — axial (negative for uplift), moment and shear in either plane
- The §12.13.4 overturning reduction as a choice
- Net uplift and column tension caught per combination; a top mat, when included, is checked for the hanging weight
Soil checks
Every ASD combination
- Service bearing, kern-aware or biaxial with partial contact solved by equilibrium
- Allowable adjusted by the geotechnical report's depth and width rules
- Overturning and sliding safety ratios per combination
Concrete design and drawings
ACI 318-25, by table
- One-way shear at d; two-way punching per Table 22.6.5.2 with αs for interior, edge and corner columns
- Flexure at the Table 13.2.7.1 section; dowels; development by Table 25.4.2.3 or Eq. (25.4.2.4a), excess-steel reduction optional
- Rebar minimum and maximum, spacing and fy checked as typed; the f′c minimum for SDC D to F flagged
- Plan and section views for every case and combination — punching perimeter, critical sections, bar layers, bearing pressure
- ACI 318-19 (the 2024 IBC edition) or ACI 318-25, chosen in Step 2; one-way shear and hooked bars follow the edition
Cantilever Retaining Wall
ACI 318-19 / 318-25 · IBC 2024 · ASCE 7-22 · TMS 402-22
- Concrete (ACI 318-19 or 318-25) or solid-grouted CMU (TMS 402-22) stem on one concrete footing.
- Seismic earth pressure by Mononobe-Okabe, Seed-Whitman or the geotechnical report.
- Groundwater, surcharges, sloped backfill, wind on the stem, and a reinforcement detail drawn to scale.
What it takes in, designs and draws
Every load a site puts on the wall; a concrete or CMU stem; every check with its derivation.
Loads it takes
From the code, the table or the report
- Earth pressure from IBC Table 1610.1 or ASCE 7-22 Table 3.2-1, both verbatim, or the geotechnical EFP; active or at-rest
- Sloped backfill with the rise over the heel; surcharges uniform, a footing behind the wall (Boussinesq), an axial load on the stem
- Groundwater with buoyant pressure, hydrostatic pressure and base uplift; passive resistance with a disregarded depth
- Wind on the stem and on a fence or guardrail; seismic by Mononobe-Okabe, Seed-Whitman or the report's ΔPAE
Stem options
Concrete or masonry
- Reinforced concrete per ACI 318-19 or 318-25
- Solid-grouted CMU — 6, 8, 10 or 12 in block, bars at a cell spacing — per TMS 402-22 Chapter 8 on the same footing
- A stem stepped once on the toe face, checked at the base and at the step with the §7.7.3 bar-cutoff rules
- Property-line walls with no toe or no heel; a shear key anywhere along the footing
- Footing and concrete stem to ACI 318-19 (the 2024 IBC edition) or ACI 318-25, chosen in Step 4
Checks and drawings
Each opens to its derivation
- Overturning and sliding FS ≥ 1.5 per IBC §1807.2.3, and ≥ 1.1 at 0.7E with seismic
- Kern-aware bearing; stem flexure and shear as a wall under axial load; heel, toe and key design
- Development lengths, laps and minimum steel per ACI 318-19 or 318-25
- A pressure diagram and free body per case and combination; a reinforcement detail drawn to scale from the engine's own bar lengths
- Pressure blocks on three scales (applied loads, bearing, passive) so a surcharge band never thins to a line
StructSuite is an independent product and is not affiliated with, sponsored by or endorsed by Simpson Strong-Tie Company Inc. or any other manufacturer named here. Simpson Strong-Tie®, DTT, HDUE, SABR, Trus Joist®, TJI®, BCI®, LPI, Microllam®, Parallam®, TimberStrand® and Versa-Lam® are trademarks of their respective owners, used only to identify supported products and design-value sources.
Recent updates
See all 261 updates- Nov 22, 2026Wood & Steel ColumnColumn: Step 6 gives the demand, the capacity and the load at the base
- Nov 22, 2026Wood-Frame Shear WallShear wall: grid spacings can be typed on a blank plan
- Nov 22, 2026Wood-Frame Shear WallShear wall: the Step 1 plan is drawn before any grid ordinate is typed
Printing reports requires Pro
This report is empty — add a module and the calculation package builds itself. Printing it requires StructSuite Pro, or a one-time Pro Week pass. Visit structsuite.com/pricing to see the options.